Applied by spraying using specialised machines, these rigid closed-cell two-component polyurethane foams are used as thermal insulation for buildings. Characterised by excellent insulating properties and low specific weight while maintaining good mechanical properties, they are used as internal and external insulation for buildings.
Closed-cell polyurethane spray foam systems — declared properties according to EN 14315-1
PUREX NG | 0428NS | 0440NS |
---|---|---|
Area of application | Industrial construction, storage and livestock facilities and cold storage for food products. Particularly suitable for insulating and sealing ceiling surfaces. | Thermal insulation for flat roofs, foundations and floors and ceilings. External fire performance of the roof according to EN 13501-5: Broof (t1). |
Characteristic features of foam | Good performance-to-mechanical strength ratio. Excellent dimensional stability of the finished product. Fast response and drying time. | The density throughout the product offers good resistance to mechanical action. The foam has received a BUREAU VERITAS type approval certificate. |
Output per one 470 kg set [m3]. | 10-11 | 7.5 |
Density throughout the product [kg/m3] | 34-37 | 55-56 |
Compressive strength [kPa] | min. 150 | min. 300 |
Water absorption [kg/m2] | ≤0.20 | ≤0.25 |
Average initial thermal conductivity coefficient [W/m*K] | 0.0215 | 0.0215 |
Reaction to fire classification according to PN-EN 13501-1 | class E | class E |